<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>proof</ParameterFamily>
<LongName>
rec_lower_hole_pos
</LongName>
<Name>
rlhp
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_400/800_Proofing</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
Indicates the distance from the leading edge of the carrier to the lower receiver vacuum holes (in mm)
used for each proof type.  These should not be adjusted once the machine has been configured properly
as they correspond to distances around the drum which are fixed-position.
</text></DescriptionText>
</Description>
<Type>
word
</Type>
<Default>
<UnnumberedList>
<li>55</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 1023 (mm)</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Partition>
cal
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../nvs/proof_cal_dlhp.xml</LinkAddress><LinkTitle>NVS: proof dlhp</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:37:25 2008 PST
</Updated>
<Links>
</Links>
</Parameter>